ICP DAS provides various sensors for fumes, particulate matters (PM2.5), gas, air quality/pollution (CO, CO2, NH3, H2S, HCHO, TVOC, SO2 ) monitoring and illuminance, liquid leakage detection in smart manufacturing, smart building and IIoT applications. A free Utility is included to confi gurate and display data in a powerful chart for the CL-200. DL-300 and DL-1000 series. Various communication interfaces are supported, so that those devices can be to be easily integrated into existing HMI or SCADA systems.
Product | DL-10 Series | DL-100 Series | iSN Series | CL-200 Series | DL-300 Series | DL-1000 Serie |
---|---|---|---|---|---|---|
Sensor |
||||||
PM2.5 | ![]() |
![]() |
||||
PM1/PM10 | ![]() |
|||||
CO/CO2 | ![]() |
![]() |
![]() |
|||
NH3/H2S | ![]() |
![]() |
![]() |
|||
HCHO/TVOC | ![]() |
![]() |
![]() |
|||
CH4 | ![]() |
|||||
SO2 | ![]() |
|||||
Illuminance | ![]() |
![]() |
||||
Temperature | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Humidity | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Interface |
||||||
RS-485 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
CAN | ![]() |
|||||
Ethernet/PoE | ![]() |
![]() |
![]() |
![]() |
![]() |
|
Wi-Fi | ![]() |
![]() |
![]() |
![]() |
![]() |
|
ZigBee | ![]() |
|||||
Product | DL-10 Series | DL-100 Series | iSN Series | CL-200 Series | DL-300 Series | DL-1000 Serie |
Protocol |
||||||
DCON | ![]() |
![]() |
![]() |
![]() |
![]() |
|
Modbus RTU | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Modbus TCP | ![]() |
![]() |
![]() |
![]() |
||
MQTT | ![]() |
![]() |
![]() |
|||
Function |
||||||
LCD Display | ![]() |
![]() |
||||
Data Logger | ![]() |
![]() |
![]() |
![]() |
|
||||||||||||||
DL-10/DL-100 Series: Temperature (T.)/Humidity (RH)/Illuminance (I.)
|
||||||||||||||
Series | Model | Sensor | DO | Interface | Protocol | Cover Color | IP Code | Power Source | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
T. | RH | Lux | ||||||||||||
DL-10/DL-11![]() |
DL-10 | Yes | Accuracy 3% RH |
– | – | RS-485 | Modbus RTU | White | – | +10 ~ +30 VDC | ||||
DL-10-BK | Black | |||||||||||||
DL-11 | White | |||||||||||||
DL-11-BK | Black | |||||||||||||
DL-100T(M)485S![]() |
DL-100TM485S
|
Yes | Accuracy 3% RH |
– | – | Black | IP66 | |||||||
DL-100TM485S-W | White | |||||||||||||
DL-100TM485PS | Accuracy 1.8% RH |
Black | ||||||||||||
DL-100TM485PS-W | White | |||||||||||||
DL-100TMS-ZT | Accuracy 2% RH |
ZigBee | Black | |||||||||||
DL-100S-E![]() |
DL-100S-E | Accuracy 3% RH |
Ethernet/PoE | Modbus TCP MQTT |
Black | PoE | ||||||||
DL-100S-E-W | White | |||||||||||||
DL-101S-WF | 2 DO | Wi-Fi | Modbus TCP HTTP |
Black | IP67 | +9 ~ +48 VDC | ||||||||
DL-101S-E | Ethernet/PoE | Modbus TCP MQTT |
IP66 | PoE or +12 ~ +48 VDC |
||||||||||
DL-101S-E-W | White | |||||||||||||
DL-110S-E![]() |
DL-110S-E | Yes | – | RS485/Ethernet/PoE | Black | IP65 | PoE or +12 ~ +48 VDC |
|||||||
DL-110S-E-W | White | |||||||||||||
DL-111S-WF | 2 DO | Wi-Fi | Modbus TCP HTTP |
Black | IP67 | +9 ~ +48 VDC | ||||||||
DL-120-E![]() |
DL-120-E | – | – | – | RS485/Ethernet/PoE | Modbus TCP MQTT |
Black | IP65 | PoE or +12 ~ +48 VDC |
|||||
DL-120-E-W | White | |||||||||||||
|
|||||||||||
Industrial Sensor
|
|||||||||||
Series | Model | Channel | Sensor | Interface | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
iSN-201![]() |
iSN-201-E | 1 |
Indoor Illuminance, Temperature and Humidity |
Ethernet, PoE, RS-485 | |||||||
iSN-201-WF | Ethernet, PoE, RS-485, Wi-Fi | ||||||||||
|
||||||
Distance Measurement
|
||||||
Series | Model | Channel | Range | Interface | Sensor Direction | Mounting |
---|---|---|---|---|---|---|
iSN-301H![]() |
iSN-301H | 1 | 5 cm~4 m | RS-485, Modbus RTU, DCON |
Horizontal | Wall Mounting |
iSN-301H/DIN | DIN-Rail | |||||
iSN-301V![]() |
iSN-301V | Vertical | Wall Mounting | |||
iSN-301V/DIN | DIN-Rail | |||||

Sensor | Range and Descriptions | Sensor | Range and Descriptions | |
---|---|---|---|---|
CO | 0 ~ 1000 ppm | H2S | 0 ~ 100 ppm | |
CO2 | 0 ~ 9999 ppm (NDIR) | CH4 | 500 ~ 7000 PPM | |
HCHO | 0 ~ 2000 ppb | PM2.5 | 0 ~ 400 μg/m3; Resolution: 1μg/m3 | |
TVOC | 0 ~ 60000 ppb (MEMS) | Temperature | -10℃ ~ 50℃ / Accuracy: ±0.6℃ | |
NH3 | 0 ~ 100 ppm | Humidity | 0 ~ 100 % RH / Accuracy: ±5% RH | |
CH4 | Alert @ 3000 ppm |
|
||||||||||
CO/CO2/HCHO/Temperature/Humidity
|
||||||||||
Models | Accessory | Sensor Type | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
RS-485 | Ethernet/PoE | Wi-Fi | Filter | Particulate Matter | Fumes | Humiture | ||||
CL-201-E | CL-201-WF | - | - | CO | Temp RH | |||||
CL-202-E | CL-202-WF | CO2 | ||||||||
CL-203-E | CL-203-WF | CO + CO2 | ||||||||
CL-204-E | CL-204-WF | HCHO + TVOC | ||||||||
CL-205-E | CL-205-WF | NH3 | ||||||||
CL-206-E | CL-206-WF | H2S | ||||||||
CL-207-E | CL-207-WF | HCHO | ||||||||
CL-208-E | CL-208-WF | TVOC | ||||||||
CL-210-E | CL-210-WF | Replaceable Filter |
PM2.5 | - | Temp RH | |||||
CL-211 | CL-211-E | CL-211-WF | CO | |||||||
CL-212 | CL-212-E | CL-212-WF | CO2 | |||||||
CL-213 | CL-213-E | CL-213-WF | CO + CO2 | |||||||
CL-220-E | CL-220-WF | Replaceable Filter |
PM1 PM2.5 PM10 Particle (PM Sizes: 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm) |
- | Temp RH | |||||
CL-221-E | CL-221-WF | CO | ||||||||
CL-222-E | CL-222-WF | CO2 | ||||||||
CL-223-E | CL-223-WF | CO + CO2 | ||||||||
CL-224-E | CL-224-WF | HCHO + TVOC | ||||||||
CL-225-E | CL-225-WF | NH3 | ||||||||
CL-226-E | CL-226-WF | H2S | ||||||||
CL-227-E | CL-227-WF | HCHO | ||||||||
CL-228-E | CL-228-WF | TVOC | ||||||||
CL-229-E | CL-229-WF | CO + CO2 + HCHO + TVOC | ||||||||
CO/CO2/HCHO/Temperature/Humidity
|
||||||||||
Models | Accessory | Sensor Type | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
RS-485 | Ethernet/PoE | Wi-Fi | Filter | Particulate Matter | Fumes | Humiture | ||||
CL-250-E | CL-250-WF ![]() |
- | O2 | - | Temp RH | |||||
CL-251-E | CL-251-WF ![]() |
CO | ||||||||
CL-252-E | CL-252-WF ![]() |
CO2 | ||||||||
CL-253-E | CL-253-WF ![]() |
CO + CO2 | ||||||||
CH4
|
||||||||||
Models | Accessory | Sensor Type | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
CAN Bus | Filter | Particulate Matter | Fumes | Humiture | ||||||
CL-20A-C | - | - | CH4 | - | ||||||

|
|||||||||||||
DL-300 Series (CO/CO2/H2S/NH3/HCHO/TVOC/Temperature/Humidity)
|
|||||||||||||
Series | Basic Type (RS-485 + Ethernet/PoE) |
Wi-Fi | Type of Sensor | IP Code | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fume Sensor | Temperature | Humidity | |||||||||||
DL-30x![]() |
DL-301 | DL-301-WF | CO | Yes | Yes | IP30 | |||||||
DL-302 | DL-302-WF | CO2 | |||||||||||
DL-303 | DL-303-WF | CO + CO2 | |||||||||||
DL-304 ![]() |
DL-304-WF ![]() |
HCHO + TVOC | |||||||||||
DL-305 ![]() |
DL-305-WF ![]() |
NH3 | |||||||||||
DL-306 ![]() |
DL-306-WF ![]() |
H2S | |||||||||||
DL-307 ![]() |
DL-307-WF | HCHO | |||||||||||
DL-308 ![]() |
DL-308-WF ![]() |
TVOC | |||||||||||
|
|||||||
DL-300 Series (CO/CO2/H2S/NH3/HCHO/TVOC/Pressure/Temperature/Humidity)
|
|||||||
Series | Basic Type (RS-485 + Ethernet/PoE) |
Wi-Fi | Type of Sensor | IP Code | |||
---|---|---|---|---|---|---|---|
Fume Sensor | Pressure | Temperature | Humidity | ||||
DL-30x-IP65![]() |
DL-301-IP65 | DL-301-WF-IP65 | CO | - | Yes | Yes | IP65 |
DL-302-IP65 | DL-302-WF-IP65 | CO2 | |||||
DL-303-IP65 | DL-303-WF-IP65 | CO + CO2 | |||||
DL-304-IP65 | DL-304-WF-IP65 | HCHO + TVOC | |||||
DL-305-IP43 | DL-305-WF-IP43 | NH3 | IP43 | ||||
DL-306-IP65 | DL-306-WF-IP65 | H2S | IP65 | ||||
DL-307-IP65 | DL-307-WF-IP65 | HCHO | |||||
DL-308-IP65 | DL-308-WF-IP65 | TVOC | |||||
DL-31X-IP65![]() |
DL-311-IP65 | DL-311-WF-IP65 ![]() |
CO | Yes | |||
DL-312-IP65 | DL-312-WF-IP65 ![]() |
CO2 | |||||
DL-313-IP65 | DL-313-WF-IP65 ![]() |
CO + CO2 | |||||
DL-314-IP65 ![]() |
DL-314-WF-IP65 ![]() |
HCHO + TVOC | |||||
DL-315-IP43 ![]() |
DL-315WF-IP43 ![]() |
NH3 | IP43 | ||||
DL-316-IP65 ![]() |
DL-316-WF-IP65 ![]() |
H2S | IP65 | ||||
DL-317-IP65 ![]() |
DL-317-WF-IP65 ![]() |
HCHO | |||||
DL-318-IP65 ![]() |
DL-318-WF-IP65 ![]() |
TVOC | |||||

The modules labelled "Available Soon" require a minimum lead time of 3 months from ordering. If there is demand, please contact our sales team.
|
|||||
|
|||||
DL-102x Series | Type of Sensor | Communication | |||
---|---|---|---|---|---|
Basic | Wi-Fi | Particle | Gas Sensor | T & RH | |
DL-1020 | DL-1020-WF ![]() |
PM1 PM2.5 PM10 Particle (PM Sizes: 0.3μm, 0.5μm, 1μm,2.5μm, 5μm, 10μm) |
- | Yes | Basic type: RS-485 + Ethernet/PoE WF type: Wi-Fi + RS-485 + Ethernet/PoE |
DL-1021 | DL-1021-WF ![]() |
CO | |||
DL-1022 | DL-1022-WF ![]() |
CO2 | |||
DL-1023 | DL-1023-WF ![]() |
CO + CO2 | |||
DL-1024 | DL-1024-WF ![]() |
HCHO + TVOC | |||
DL-1025 | DL-1025-WF ![]() |
NH3 | |||
DL-1026 | DL-1026-WF ![]() |
H2S | |||
DL-1027 | DL-1027-WF ![]() |
HCHO | |||
DL-1028 | DL-1028-WF ![]() |
TVOC | |||
DL-1029 | DL-1029-WF ![]() |
SO2 | |||
|
|||||
|
|||||
DL-103x Series | Type of Sensor | Communication | |||
---|---|---|---|---|---|
Basic | Wi-Fi | Particle | Gas Sensor | T & RH | |
DL-1034 | DL-1034-WF ![]() |
PM1 PM2.5 PM10 Particle (PM Sizes: 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm) |
HCHO + TVOC | Yes | Basic type: RS-485 + Ethernet/PoE WF type: Wi-Fi + RS-485 + Ethernet/PoE |
DL-1038 | DL-1038-WF | TVOC | |||
|
|||||
|
|||||
DL-105x Series | Type of Sensor | Communication | |||
---|---|---|---|---|---|
Basic | Wi-Fi | Particle | Gas Sensor | T & RH | |
DL-1050 | DL-1050-WF ![]() |
O2 | - | Yes | Basic type: RS-485 + Ethernet/PoE WF type: Wi-Fi + RS-485 + Ethernet/PoE |
DL-1051 | DL-1051-WF ![]() |
CO | |||
DL-1052 | DL-1052-WF ![]() |
CO2 | |||
DL-1053 | DL-1053-WF ![]() |
CO + CO2 | |||
DL-1054 ![]() |
DL-1054-WF ![]() |
HCHO + TVOC | |||
DL-1055 ![]() |
DL-1055-WF ![]() |
NH3 | |||
DL-1056 ![]() |
DL-1056-WF ![]() |
H2S | |||
DL-1057 ![]() |
DL-1057-WF ![]() |
HCHO | |||
DL-1058 ![]() |
DL-1058-WF ![]() |
TVOC | |||