DL-1020
Introduction
The DL-1000 can measure the concentration of particles in the air and various gas concentrations related to human health can also be measured. In addition, DL-1000 can record data and send alarm when concentration is too high.
● Particles:
Concentration of particles (PM1, PN2.5, PM10), particle count (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm)
● Concentration of various gas:
CO/ CO2/ O2/ HCHO/ TVOC/ NH3/ H2S/ SO2
DL-1000 stores up to 180,000 downloadable records, including date and time stamps. Real-time data can be accessed from the DL-1000 series Data Logger from anywhere and at any time using the free Windows software, the iOS App or the Android App, as long as they are connected to the same local network as the Data Logger. The DL-1000 series Data Logger can be connected via widely used communication interfaces including RS-485, Ethernet and meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system. The DL-1000 series is designed for industrial applications in harsh environments that provides IP43 protection rating. The rugged RJ-45 ensures tight, robust connections, and guarantees reliable operation, even for applications that are subject to high vibration and shock.
► Multi-platform Remote Access Software
Real-time data from the DL-1000 Data Logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the Data Logger


► Supports the MQTT Protocol for IoT Applications

► Simple and powerful utility
The iAir Utility can be used to configure the modules, monitor real-time data, group DL-1000 modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.


► Replaceable Filter Patch (FLT-C001)
The windshield filter of DL-1000 is replaceable and with replaceable patches, which makes it easy for user to replace by themselves. Commercially available sensors are easily affected by dust when used outdoors, which may result in continuous alarm readings and the inability to correctly measure ambient gases. They need to be sent back to the original factory for repair, which increases costs and downtime. ICP DAS’s design allows users to easily replace the filter, reducing maintenance costs and time caused by dust blockage.


Applications
► Intelligent Street Lighting in Smart City
DL-1000 series products, with standard industrial communication protocol Modbus RTU/TCP, can integrate with smart city to achieve outdoor air quality monitoring such as O2, CO, CO2, SO2, TVOC, HCHO, and Particle Matter 1/2.5/10. Since these aerosol could accumulate around the sensor and would cause error record after using for a period of time, DL-1000 supports replaceable dust filter patches to easily change the patches inside the filter hood rather than uninstall the device.


► Outdoor Mobile Air Quality Detection Application
In developed countries, the air quality detection, statistics and evaluation is in urgent need for improvement. In a vast area, it can only rely on the vehicle to move to record status of air quality in the area, and to extract the off-line data and send it back. ICP DAS's DL-1000 series can integrate with our 3G/ 4G controllers to transmit data back to the control center wirelessly.


► Factory Gas Detection Application
In some factories, H2S is one of the harmful gases. Since the colorless and odorless are two characteristics quite hard to find or feel, sometimes the workers inside the factory get injured inevitably. Joint liability from the injury brings the company massive fines.
DL-1026 H2S detector module can be put on the spot. It is equipped with standard industrial protocols and with high flexibility to integrate information from devices and transmit it back to the control center. When the concentration of gas is too high, DL-1026 can also send alarm signals to inform relative personnel to evacuate people there.

DL-1026 H2S detector module can be put on the spot. It is equipped with standard industrial protocols and with high flexibility to integrate information from devices and transmit it back to the control center. When the concentration of gas is too high, DL-1026 can also send alarm signals to inform relative personnel to evacuate people there.

Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
This combination include other products.
Similar Products
LED Indicators | |
---|---|
Status | PWR: Green for normal operation Link: Green for the Ethernet-linked S1 ~ S4: Red for an alarm condition |
System | |
---|---|
Security | IP filter (whitelist) and Password (web) |
Alarm | PM1/PM2.5/PM10 /RH/Temperature/ Real Time Clock |
Real Time Clock | Yes |
Data Logger | Yes, up to 180,000 records |
Relay Output | PhotoMOS Relay, Form A x4, SPST 100 VDC @ 1 A |
Temperature Measurement | |
---|---|
Range | -20 ~ +50°C |
Resolution | 0.1°C |
Accuracy | ±0.6°C |
Humidity Measurement | |
---|---|
Range | 0 ~ 100% RH |
Resolution | 0.1% RH |
Accuracy | ±5% RH |
Life Time | 10 years |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
PM1/PM2.5/PM10 Measurement | |
---|---|
Range | 0 to 1,000μg/m3 ( Laser Type) |
Resolution | 1μg/m3 |
Accuracy | ± 10% of FSR. |
Response Time | 1 sec |
Warm-up Time | 20 sec |
Life Time | 5 years, Customer has to replace the filter patch. |
Particle | |
---|---|
Sizes | 0.3μm, 0.5μm,,1μm, 2.5μm,,5μm, 10μm |
Ethernet | |
---|---|
Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 |
Protocol | Modbus TCP(Ethernet) and MQTT(Ethernet) |
COM Ports | |
---|---|
Baud Rate | 1200 ~ 115200 bps |
Protocol | Modbus/RTU(RS-485) |
Power | |
---|---|
Consumption | PoE: 3.0 W (Max.) Non-PoE: 2.6 W (Max.) |
Powered from PoE | IEEE 802.3af, Class 1 (48 V) |
Powered from Terminal Block | +8 ~ +48 VDC |
Mechanical | |
---|---|
Dimensions (mm) | 130 x 210 x 70 (W x L x H) |
Installation | DIN-Rail or Wall Mounting |
Ingress Protection Rating | IP43 |
Environment | |
---|---|
Operating Temperature | -20 ~ +50°C |
Storage Temperature | -30 ~ +75°C |
Humidity | 10 ~ 90% RH, Non-condensing |