All I-8000, compact PAC, have similar form factor and system architecture. With different software or communication interface, they can be classfied to several solutions as following
Will be available
Available soon
Will be phased out
Phased out
Modbus RTU I/O Expansion Unit
Modbus is a communication protocol developed by Modicon in 1979 for linking devices with Modicon PLCs using a master/slave relationship. Different versions of Modbus today include Modbus RTU, Modbus ASCII and Modbus TCP. Where Modbus RTU and ASCII are based on serial communication like RS-232 and RS-485, and Modbus TCP is based on Ethernet communication. It's a standard, truly open and widely used in industrial automation field.
The iP-8000-MRTU series is an I/O unit with Modbus protocol. It supports most of high profile I-8K and I-87K series I/O modules. SCADA and HMI software can easily access variant I/O signals via the iP-8000-MRTU.
���F�W���o�ⶵ�S��A���ױN�ܦ��D�`�e���C���p���@�ӼҲշl�[�F�A�u�@�H���u�ݭn��@�ӷs���ҲձN�l�a�����@�Ӵ����Y�i�C��Өt�Τ��ݭn���F���צӰ����A�ӥB I/O �Ҳժ��պA�]�|�۰ʳQ CPU �Ҳէ����C
Modbus TCP I/O Expansion Unit
Modbus is a communication protocol developed by Modicon in 1979 for linking devices with Modicon PLCs using a master/slave relationship. Different versions of Modbus today include Modbus RTU, Modbus ASCII and Modbus TCP. Where Modbus RTU and ASCII are based on serial communication like RS-232 and RS-485, and Modbus TCP is based on �A�Ӻ� communication. It's a standard, truly open and widely used in industrial automation field.
The iP-8000-MTCP series is an I/O unit with Modbus protocol. It supports most of high profile I-8K and I-87K series I/O modules. SCADA and HMI software can easily access variant I/O signals via the iP-8000-MTCP.
Intelligent Remote Redundant Ethernet I/O expansion unit
The unit is the intelligent remote redundant I/O unit with Modbus TCP protocol. It can be equipped with 2 power modules, 2 communication module, 8 I/O modules. The unit offers redundancy options for various functions- ranging from power redundancy to I/O redundancy. Besides, there are most of I/O modules, such as DI, DO, AI, AO, PI, PO, HART and etc, can be used in the units. Only the F-8K modules can be plugged in the unit.
The most important features are
Auto configuration
Each slot configuration can be pre-configured and stored in the CPU module, Once a module is plug in, the CPU module will write the pre-configured data to the module.
Hot Swap
All F-8K modules circuit design allow it to be hot swapped. The unit don't need to power off while swapping I/O modules.
Redundancy
Support redundant communication, power and I/O function to enhance the reliability of the system.
Open Communication protocol
Due to the Modbus TCP protocol, iDCS-8830 can be integrated in various PC/PAC/PLC system easily.