| Input |
| Voltage range |
85 ~ 264 VAC
120 ~ 370 VDC |
| Frequency range |
47 ~ 63 Hz |
| Efficiency (Typ.) |
87% |
| Leakage current (max.) |
1.8 A/115 VAC
1 A/230 VAC |
| Inrush Current (Typ.) |
COLD START 30 A/115 VAC
60 A/230 VAC |
| Leakage current |
<1 mA / 240 VAC |
| Output |
| DC Voltage |
48 V |
| Rated Current |
1.25 A |
| Current Range |
0 ~ 1.25 A |
| Rated power |
60 W |
| Ripple & noise (max.) Note.2 |
200mVp-p |
| Voltage ADJ. range |
48 ~ 56 V |
| Voltage Tolerance Note.3 |
±1.0% |
| Line Regulation |
±1.0% |
| Load regulation |
±1.0% |
| Setup, rise Time Note.5 |
500 ms, 30 ms/230 VAC
500 ms, 30 m/115 VAC at full load |
| Hold up time (Typ.) |
50 ms/230 VAC
20 ms/115 VAC at full load |
| Protection |
| Overload |
105 ~ 150% rated output power |
| Protection type : Constant current limiting, recovers automatically after fault condition is removed |
| Over voltage |
57.6 ~ 64.8V |
| Protection type : Shut down o/p voltage, re-power on to recover |
| Function |
| DC OK signal |
Relay contact rating(max.): 30V/1A resistive |
| Environmental |
| Working temp. |
-20 ~ +70°C (Refer to output load derating curve) |
| Working humidity |
20 ~ 90% RH non-condensing |
| Storage TEMP., humidity |
-40 ~ +85°C , 10 ~ 95% RH |
| TEMP. Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
Component : each along X, Y, Z axes ;
Mounting : Compliance to IEC60068-2-6 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. |
| Safety & EMC (Note 4) |
| Safety standards |
UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24V,48V only) |
| Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25°C 70%RH |
| EMI Conduction & Radiation |
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B |
| Hsrmonic current |
Compliance to EN61000-3-2,-3 |
| EMS immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
| DC OK Relay Contact |
| Contact Close |
When the output voltage reaches the adjusted output voltage. |
| Contact Open |
When the output voltage drop below 90% output voltage. |
| Contact Ratings (max.) |
30V/1A resistive load |
| Others |
| MTBF |
299.2K hrs min.
MIL-HDBK-217F (25°C) |
| Dimension (W x H x D) |
40 mm x 90 mm x 100 mm |
| Packing |
0.33Kg; 42pcs/14.8Kg/0.82CUFT |
| NOTE |
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
|