| Input |
| Voltage range |
100-250 VDC |
| Frequency |
50/60 Hz |
| Input current |
0.05 ~ 0.52 A |
| LEAKAGE CURRENT(max.) |
0.75 mA/240 VAC |
| Output |
| Voltage |
48 VDC |
| Output current |
0.52 A |
| Ripple |
180mVp-p |
| Over voltage protection |
Yes (clamp by Zener diode). |
| Over current protection |
130 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| Over load protection |
105 ~ 135% rated output voltage
Protection type : Recovers automatically after fault condition is removed |
| Temperature coefficient |
±0.04%/°C (0~50°C) |
| Efficiency |
82% (Typ.) |
| Hold-up time |
16ms at full load |
| Line regulation |
±1% (Line regulation is measured from low line to high line at rated load) |
| Load regulation |
±2% (Load regulation is measured from 20% to 100% rated load) |
| General |
| MTBF |
500Khrs min. MIL-HDBK-217F(25°C) |
| Environmental |
| Operating Temperature |
0 °C ~ +50°C |
| Storage Temperature |
-20 °C ~ +85°C |
| Humidity |
20% ~ 90% RH, non-condensing |
| Derating |
Derated from 100% at +38 °C |
| SAFETY & EMC |
| Safety standards |
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336 approved |
| Withstand voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG:100M Ohms / 500 VDC / 25 / 70% RH |
| EMI conduction & radiation |
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B |
| Harmonic current |
Compliance to EN61000-3-2,3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A |