ICP DAS news & events

2005
Jun/03/2005

DCON_ActiveX V4.3.2 is released now

DCON_ActiveX has been updated to the version 4.3.2

Modify:
DCON_ActiveX.pdf and InstallOCX.pdf

Add:
1. Digital Output Modules:87041,7045,7055
2.
Digital Input Modules:87040,7055

You can download the program with the two ways as below. Download the complete package rom
ftp://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_activex/
http://www.icpdas.com/download/7000/7000.htm

BACK

Apr/14/2005

8000E-MTCP update

Go to download area

Modbus Utility updated to version 1.3.2

  1. Supports 87040,87041

8000E-MTCP firmware updated to version 1.3.5

  1. Supports 87040, 87041
  2. Fixes bug of online/offline statuses of I/O modules

BACK

Apr/13/2005

NAPOPC DA Server Update

NAPOPC DA Server has been updated to version 2.18 and added the following component.

  • Add auto scan function for Modbus devices (M7K).
  • Add configuration for load files automatically or manually when clients connect to server.
  • Add configuration for show or hide icon on system tray when clients connect to server.
  • Modify OnMonitor function for release com port correctly.
  • Modify a bug for I-8037 can't get correct value on channel 8 to 15.
  • Add a following module: M7019 M7041 M7052 M7053 M7055 M7060 M7067

Please download it from http//www.icpdas.com/products/software/napopc/napopc.htm

BACK

Apr/11/2005

7188E-MTCP update

Go to download area

Modbus/TCP and Modbus/RTU firmware and SDK for I-7188E, I-7188XA and I-7188XB are updated to version 1.6.0. The new features are:

  1. Improves communication performance. Each communication takes 3~6ms less than before.
  2. Provides SDK for Microsoft C compiler (MSC600 and MSVC1.52).
  3. Provides more demo programs for Xboard.
    X107, X110, X202, X304, X310

BACK

Mar/24/2005

The NWH650 have already phased out

The NWH650 have already phased out,and the NWH660 replace NWH650.

For more information, please refer to
http://www.icpdas.com/products/modem/nwh650.htm
http://www.icpdas.com/products/modem/nwh660.htm

BACK

Mar/22/2005

Web HMI demo is available on the Web

Web HMI demo now is available on the Web. Please visit 61.218.42.10 and entering username = level2 , password = level2. Click here to see more information (Web_HMI.ppt in ZIP format).

BACK

Mar/14/2005

Company trip

To All of Our Valued Customers

Company's Trip Notification

Please kindly take note that ICP DAS CO., LTD.
Will be having the Company's Trip from the MARCH 16 to MARCH 20 of 2005.

All shipment arranges, E-mails and phone calls will be responded at MARCH 21.

We apologized for any inconvenience during this period.

Thank you.

Yours faithfully

ICP DAS CO., LTD

BACK

Feb/17/2005

I-8437-80 & I-8837-80 is released, 2 - 4 times faster

  • The I-8437-80 / I-8837-80's CPU is 80MHz compared to the I-8437/8837's 40MHz CPU.
  • The speed of the ISaGRAF program running in the I-8437-80 / I-8837-80 is about 2 to 4 times faster than I-8437/8837.
  • The other feature is the same as the I-8437/8837.

Please refer to http://www.icpdas.com/products/8000/I-8417.htm

BACK

Feb/17/2005

ISaGRAF Driver Update

I-8xx7, I-8xx7-80, hardware driver upgraded to new version.

Feb/05/2005

DCON_ActiveX V4.3.1 is released now

DCON_ActiveX has been updated to the version 4.3.1

Modify:

  • DCON_ActiveX.pdf and InstallOCX.pdf

  • Send_Cmd and SendBinary and Checksum bug

  • AnalogIn for 7016 can set parameter to selecte channel to read Analog data

  • DigitalInCounterRead for 8K and 87K modules

  • AnalogIn8 2's complement bug

Add:

  • Digital Output Modules:8037,8050,8069

  • Digital Input Modules:7058,87058

  • Analog Input Modules:7015,7019R

  • OCX AnalogInFsr function support for 8K and 87K modules


  • AnalogInHex function support for 8K and 87K modules

You can download the program with the two ways as below.Download the complete package from ftp://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_activex/
http://www.icpdas.com/download/7000/7000.htm

BACK

Feb/03/2005

M-7000 Series: Remote I/O modules with Modbus RTU support

The M-7000 series is a family of network data acquisition and control modules that support Modbus RTU and DCON protocols.With the Modbus RTU protocol, it can easily communicate with most popular SCADA/ HMI software and PLC. It has the same form factor as the I-7000 series.

Features

  • 3000 VDC isolation (inter-module)

  • High voltage overload protection: M-7017R, M-7018R, M-7019R, M-7055

  • High digital input voltage, 50 Vdc: M-7055

  • Short circuit protection for digital output: M-7055

  • Open thermocouple detection: M-7018R, M-7019R

  • Open RTD detection: M-7015, M-7033

  • Individual channel configurable: M-7015, M-7019R

The following modules are available:

  • 8-channel analog input module: M-7017

  • 8-channel analog input module with high voltage overload protection: M-7017R

  • 8-channel thermocouple input module: M-7018R

  • 8-channel thermocouple input module with high voltage overload protection: M-7018R

  • 8-channel universal analog input module with high voltage overload protection: M-7019R

  • 4-channel relay output and 4-channel isolated digital input module: M-7060/M-7060D

  • 7-channel relay output module: M-7067/M-7067D

The following modules will be available:

  • 6-channel RTD input module: M-7015

  • Strain gauge input module: M-7016/M-7016D

  • 3-channel RTD input module: M-7033

  • 14-channel isolated digital input module: M-7041/M-7041D

  • 8-channel isolated digital input module: M-7052/M-7052D

  • 16-channel digital input module: M-7053/M-7053D

  • 8-channel isolated digital output and 8-channel isolated digital input module: M-7055/M-7055D

For more details, please refer to http://www.icpdas.com/products/7000/7000_index.htm#m7000.

BACK

Jan/14/2005 ICP DAS New Product:VXC-142i: PCI Bus, 2-port Isolated RS-422/485 Communication Board

The VXC-142i card provides two independent RS-422/RS-485 serial ports and can withstand isolation voltage up to 3KV. Each port can be configured as either RS-485 for half-duplex or RS-422 for full-duplex communication.

The user can select a specified COM port number manually by setting dip switch, or let the driver to choose an available number automatically. The driver provides a maximum of 128KB software FIFO for each COM port under Windows. It's practical for large file transmission.

In the harsh industrial environment, the on board surge protection can protect the computer and equipment from being damaged by high potential voltage.

Advantages

  • Built-in COM-Selector

  • Self-Tuner Inside

  • 3KV Isolation

  • Up to 128KB software FIFO for each COM port under Windows

  • Short Card Design

Features 

  • Supports PCI bus, Plug and Play

  • Provides 2-port Isolated RS-422/485

  • Provides surge protection

  • LED diagnostic indicators

  • Provides DOS Lib and sample programs (with source code)

  • Supports Windows NT 4.0 (Standard COM port interface)

  • Supports Windows 2K/XP/2003 (Standard COM port interface)

  • Supports Linux driver (tty device interface)

For more information, please refer to VXC-142i.

BACK

Jan/11/2005 I-8KE4-MTCP-G and I-8KE8-MTCP-G:Modbus/TCP I/O unit is available.   

Introduction

I-8KE4-MTCP-G and I-8KE8-MTCP-G are Modbus/TCP I/O units with Modbus communication protocol. They support most of 8K and 87K series I/O modules, such as DI, DO, DIO, AI, AO, etc.. Most SCADA software support Modbus communication protocol, thus users can easily and quickly integrate remote I/Os to the SCADA software as data acquisition and monitor to apply to environment monitoring, power management, factory automation, etc.

Features

·    Supports IPv4

·    Supports Modbus/TCP communication protocol at Ethernet port.

·    Supports Modbus/RTU communication protocol at RS-232 port.

·    Supports 8K and 87K series DI/DO/AI/AO/Counter/Frequency modules

·    I/O configurable via the Ethernet (Using the Modbus Utility)

·    I/O scan engine
The engine can automatically scan I/O modules plug in slots and range I/O registers address to continuous to have high-data-density registers to get best communication efficiency.

·    Detection of I/O module communication status (online/offline).

·    The SMMI of the panel can be used to 

            1. Configure the network setting (IP, Mask, Gateway)  

                2. Set the offset value of AI/AO module

·    Allowed a maximum of 8 host PCs access simultaneously

·    Firmware updateable (via the RS-232 port)

·    Firmware programmable
We provide the Modbus SDK allowing users customized the Modbus firmware. 

Please refer to  http://www.icpdas.com/products/8000/I-8KE4_8KE8_MTCP_Eng.htm for further information.

BACK

old news & events