PM-4324P-MTCP

Multi-circuit Smart Power Meter
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP
PM-4324P-MTCP

Features

• Supports bidirectional kWh metering
• 8 Three Phase Circuits or 24 Single Phase Circuits
• True RMS Power Measurements
• Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
• Supports CTs with 333 mV voltage output
• Voltage Measurements Up to 500 V
• Total Harmonic Distortion (THD)
• Support Modbus TCP Protocol
• Support 2 Power Relay Output (Form A)
• Compliant with IEC 61010-1 and EN 61010-1 standards
RoHS WEEE

Introduction

The PM-4324P series from ICP DAS is a multi-circuit smart power meter capable of monitoring up to 8 three-phase
circuits or 24 single-phase circuits, or any combination of both. It measures up to 24 current inputs via external
current transformers (CTs), offering flexibility ideal for multi-tenant facilities such as residential complexes, office
buildings, and shopping malls. With its compact form factor, the PM-4324P can be conveniently installed inside existing
panelboards or flush-mounted nearby, avoiding the need for costly retrofitting or allocating extra installation space.
The PM-4324AP is equipped with two independent main voltage inputs, allowing it to monitor two different power systems
separately. Alternatively, the two inputs can be connected in parallel and used as a single main circuit input, providing
functionality equivalent to the PM-4324P. This design offers greater flexibility and adaptability for various applications.
Both PM-4324P and PM-4324AP do not include CTs by default; users can select compatible CTs with a 333 mV voltage
output. Rogowski coils are not supported.

Applications


• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES PM-4324P-MTCP     CR DESCRIPTIONModbus TCP, multi-circuit power meter, supports 333 mV CTs, not for Rogowski coils (RoHS)
This combination include other products.
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops 3-phase: 8;
1-phase: 24 @ 1P2W-1CT, 8 @ 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Frequency 50/60 Hz
W Accuracy Accuracy is approximately 2–5% (PF = 1), depending on the CT used. The CT ratio must be set correctly.
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh),Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
Ethernet
Protocol Modbus TCP
Power
Input Range +85 ~ +264 VAC (277 VAC available)
Consumption 6 W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63 Hz), 5 A @ 30 VDC
Mechanical
Casing Metal
Dimensions (mm) 237 x 57 x 134 (W x L x H)
Installation DIN-Rail & wall mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing