HRT-711-UTA
Introduction
The HRT-711-UTA Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the utility software for users to configure the HRT-711-UTA. By using this module, users can integrate their HART devices into Modbus network easily.
Applications

- Industrial Automation
- Factory Automation
- Process Automation
- Etc…
Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
This combination include other products.
Similar Products
Ethernet | |
---|---|
Ports | 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX) |
COM Ports | |
---|---|
Ports | RS-232(3 wires) |
HART | |
---|---|
Ports | 1 |
Device | 2-wired or 4-wired HART devices |
Topology | Point to Point or Multi-Drop |
Data | Only Digital Data |
Frame Type | Short and Long Frame |
Burst Mode | Supported |
Max. HART Device | 15 |
Loop Resistor | 250 Ω resistor by Jumper |
Isolation | UL1577 Spec. |
Protocol | 2-pin screwed terminal block |
Power | |
---|---|
Reverse Polarity Protection | Power reverse polarity protection, Over-voltage brown-out protection |
Input Range | Unregulated +10 ~ +30 VDC |
Consumption | 1 W |
Mechanical | |
---|---|
Dimensions (mm) | 72 x 35 x 121 (W x L x H) Detail |
Installation | DIN-Rail or Wall Mounting |
Environment | |
---|---|
Operating Temperature | -40 ~ +75 °C |
Storage Temperature | -40 ~ +80 °C |
Humidity | 5% ~ 95% RH, Non-condensing |
- Provide the system and communication configuration of HRT-711-UTA
- Provide the Modbus address table for HART command data
- Provide the diagnostic information of HRT-711-UTA module and HART device
- Provide send / receive HART command to access HART device
- Provide "Load/Save" module configuration file to apply to other HRT-711-UTA quickly
Modbus Support
Support the following Modbus commands.
Code | Name | Description |
---|---|---|
01 | Read Coil Status | Read the ON/OFF status of discrete outputs in the slave |
02 | Read Input Status | Read the ON/OFF status of discrete inputs in the slave |
03 | Read Holding Registers | Read the binary contents of holding registers in the slave |
04 | Read Input Registers | Read the binary contents of input registers in the slave |
05 | Force Single Coil | Write a single output to either ON or OFF in the slave |
06 | Preset Single Register | Write an integer value into a single register in the slave |
15 | Force Multi. Coils | Write each coil in the sequence of coils to either ON or OFF in the slave |
16 | Preset Multi. Registers | Write a block of contiguous registers in the slave |