HRT-710-UTA
Introduction
The HRT-710-UTA Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the software utility, HG_Tool, for module configuration and HART device diagnosis. By using these modules, users can integrate their HART devices into Modbus network easily and quickly.
Model | HRT-710 | HRT-310 |
---|---|---|
Din Rail Installation | Horizontal | Upright |
HART Signal | Standard | Enhanced send/receive signal (For long distance comm.) |
Loop Power | No | Support (module provides +30V output) |
Built-In Resistor | 250 Ohm (1/4W) | 250 Ohm (1W) |
Applications

- Industrial Automation
- Factory Automation
- Process Automation
- Etc…
HRT-710-UTA, a HART master to Modbus slave gateway, is applied to integrate the information from these HART flow meters into the customer's HMI system. Through the HRT-710-UTA, all of the HART flow meters will be regarded as Modbus slave devices and the HMI system can use the built-in Modbus RTU communication to access these HART flow meters easily.
More than 250 HART device information needs to be integrated to surveillance center. In PC side, uses 3 pieces of PCI cards (VXC-148U, for 24 channels RS-485 expansion). I-2542A and I-2542B (RS-485 to Fiber) are used in every RS-485 channel to extend RS-485 communication distance. There are about 20 pieces of HRT-710-UTA modules used in every RS-485 channel with the different station ID. Through the structure, SCADA or HMI system can integrate all HART device information via Modbus protocol easily and quickly.
Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
Similar Products
COM Ports | |
---|---|
Ports | RS-232(3 wires) / RS-422 / RS-485 |
Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
Protocol | Modbus RTU / Modbus ASCII |
HART | |
---|---|
Ports | 1 |
Device | 2-wired or 4-wired HART devices |
Topology | Point to Point or Multi-Drop |
Data | Only Digital Data |
Frame Type | Short and Long Frame |
Burst Mode | Supported |
Max. HART Device | 15 |
Loop Resistor | 250 Ω (1/4W) by Jumper |
Isolation | UL1577 Spec. |
Protocol | 2-pin screwed terminal block |
Loop Power | No |
Power | |
---|---|
Reverse Polarity Protection | Power reverse polarity protection, Over-voltage brown-out protection |
Input Range | Unregulated +10 ~ +30 VDC |
Consumption | 1 W |
Mechanical | |
---|---|
Dimensions (mm) | 72 x 35 x 121 (W x L x H) Detail |
Installation | DIN-Rail or Wall Mounting (Horizontal) |
Environment | |
---|---|
Operating Temperature | -40 ~ +75 °C |
Storage Temperature | -40 ~ +80 °C |
Humidity | 10% ~ 90% RH, Non-condensing |
- Provide the system and communication configuration of HRT-710-UTA
- Provide the Modbus address table for HART command data
- Provide the diagnostic information of HRT-710-UTA module and HART device
- Provide send / receive HART command to access HART device
- Provide "Load/Save" module configuration file to apply to other HRT-710-UTA quickly
Modules Support
Support the following Modbus commands.
Code | Name | Description |
---|---|---|
01 | Read Coil Status | Read the ON/OFF status of discrete outputs in the slave |
02 | Read Input Status | Read the ON/OFF status of discrete inputs in the slave |
03 | Read Holding Registers | Read the binary contents of holding registers in the slave |
04 | Read Input Registers | Read the binary contents of input registers in the slave |
05 | Force Single Coil | Write a single output to either ON or OFF in the slave |
06 | Preset Single Register | Write an integer value into a single register in the slave |
15 | Force Multi. Coils | Write each coil in the sequence of coils to either ON or OFF in the slave |
16 | Preset Multi. Registers | Write a block of contiguous registers in the slave |