CAN-8124-G
Introduction
The CAN-8124 main control unit is specially designed for the slave device of DeviceNet protocol. It follows the Specification of DeviceNet. In order to expand I/O channel more flexible, an CAN-8124 supports 1 slot for I/O expansion and suits with a lot of ICP DAS DI/AI/DO/AO modules. Users can choice DI/DO/AI/AO modules of I-87K series or I-8000 series to fit the customized practice applications. In addition, we also provide CAN Slave Utility to allow users to create the EDS file dynamically. The EDS file is based on DeviceNet and can be compatible with different DeviceNet master interfaces.

Applications

- Automotive
- Food & Beverage
- Packaging
- High-speed Assembly
- Pulp & Paper
- Semiconductor Fabrication
- Control System...etc.
Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
Similar Products
CPU Module | |
---|---|
CPU | 80186, 80 MHz or compatible |
EEPROM | 16 KB |
Flash | 512 KB |
NVRAM | 31 bytes (battery backup, data valid for up to 10 years) |
SRAM | 512 KB |
Real Time Clock | Yes |
Watchdog Timer | Watchdog IC |
LED Indicators | |
---|---|
Status | 1 x Power 2 x DeviceNet status |
I/O Expansion | |
---|---|
Slots | 1 slots |
DeviceNet | |
---|---|
Controller | NXP SJA1000T with 16 MHz clock |
Ports | 1 |
Connection Supported | 1 connection for Explicit Messaging 1 connection for Polled I/O 1 connection for Bit-Strobe I/O 1 connection for COS/Cyclic I/O |
Baud Rate | 125 k, 250 k, 500 k |
Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
Terminal Resistor | Jumper for 120 Ω terminal resistor |
Specification | Volume I, Release 2.0 & Volume II, Release 2.0 |
Node ID | 0 ~ 63 |
Shutdown Message | Yes |
Subscribe | Group 2 Only Server |
Power | |
---|---|
Input Range | +10 VDC ~ +30 VDC |
Consumption | 1.7 W |
Mechanical | |
---|---|
Dimensions (mm) | 64 x 119 x 91 (W x L x H) |
Installation | DIN-Rail |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 ℃ |
Storage Temperature | -30 ~ +80 ℃ |
Humidity | 10 ~ 90% RH, Non-condensing |
In the CAN-8124/CAN-8224 device, ICPDAS provides CAN Slave Utility to produce the specific EDS file with the plugged in modules in off-line mode. After finishing the utility configuration, it can create the EDS file. There is also much DeviceNet information of the CAN-8x24 in the EDS file. It is not only for DeviceNet master interface but also for users to know more information about the slave device. Users also can use the default configuration for general DI/DO/AI/AO. And users only need to set the MAC ID and Baud rate by hardware rotary switch. Then, after wire connection and the CAN-8x24 powered on, it can work normally on the CAN bus network through DeviceNet protocol.
Design Flowchart
The following simple steps show how to use CAN-8x24 in DeviceNet protocol.