Introduction:
The I-2533CS-FD-A/B series provides a reliable fiber-optic connection between two CAN/CAN FD networks. It converts electrical CAN/CAN FD signals into optical signals for transmission over single-mode fiber.

Key Benefits:
  • Single-fiber transmission: WDM technology enables bidirectional CAN/CAN FD data transmission over a single fiber, reducing cabling requirements and deployment costs.
  • Extended CAN network distance: Fiber-optic transmission overcomes the CAN bus distance limitation associated with baud rate, enabling longer communication distances.
  • Network isolation: A bus error on one CAN network does not affect the operation of the other CAN network.
  • Flexible baud rates: The two CAN networks can operate at different CAN baud rates, providing greater application flexibility.
  • UL-certified options: The -UL and -UL-UTA models are UL certified for enhanced safety and reliability.
  • Conformal coating option: The -UL-UTA models feature conformal-coated PCBs for enhanced protection against moisture, dust, and corrosion, making them suitable for high-humidity and high-salinity environments.
 
Features:
  • Protocol Support: Complies with ISO 11898-2 and supports CAN 2.0A/2.0B and CAN FD (ISO and Non-ISO/Bosch).
  • Flexible Baud Rate Settings:
    • CAN FD (Data Phase): 100 kbps to 10 Mbps
    • CAN: 10 kbps to 1 Mbps
  • Fiber Break Detection: Provides real-time monitoring of the fiber link status.
  • Smart Traffic Control: Supports CAN message filtering and simple message routing via the "Group ID" parameter.
  • Easy Maintenance: DIP switches allow quick baud rate configuration and enable/disable the 120 Ω termination resistor; a USB port supports firmware updates.
 
Specifications:
Model Comparison Table
Model Operating Temperature UL Certification
I-2533CS-FD-A
I-2533CS-FD-B
-25 ~ +75 °C
I-2533CS-FD-A-UL
I-2533CS-FD-B-UL
-25 ~ +70 °C
I-2533CS-FD-A-UL-UTA
I-2533CS-FD-B-UL-UTA
-40 ~ +70 °C
Note 1: The -A and -B series must be used as a pair.
Note 2:
The -UTA version features a conformal-coated PCB that provides protection against moisture, dust, and corrosion, making it particularly suitable for high-humidity and high-salinity environments such as coastal areas, marine applications, and water treatment facilities. Even when installed in a waterproof enclosure, the conformal-coated version is recommended for enhanced protection.